This product has been discontinued.

The manufacturer has discontinued this product permanently. Please see the alternative product below.

27k BTU 23 SEER MrCool Olympus Ductless Heat Pump Split System - 2 Zone Wall Mounted - 18k+18k

Item: HA11737
Models: MULTI3-27HP230V1, O-MULTI18HP-WMAH-230
Condition: New

27k BTU 23 SEER MrCool Olympus Ductless Heat Pump Split System - 2 Zone Wall Mounted - 18k+18k Zoom

Photo Gallery

Just because you live in a large space doesn't mean you can't use a MRCOOL Olympus Ductless Heat Pump Split System to get the comfort, efficiency, and savings you want. This 36k system gives you dual wall-mounted air handlers with 18k heating and cooling power each. Energy-saving features include Sleep Mode and Louver Position Memory. Each air handler leads back to the MRCOOL MULTI3-27HP230V1 condenser with 36k BTU of power, and a host of energy efficient features that include ozone-safe R-410A refrigerant. Variable-speed technology helps this system operate at 23 SEER.

Get everything right and save time

Contact an expert now.

Call: 1-270-575-9595

or click here to chat

This Bundle Includes

27k BTU MrCool Olympus Ductless Heat Pump Condenser - 3 Zone 27k BTU MrCool Olympus Ductless Heat Pump Condenser - 3 Zone Item: HA11046 Model: MULTI3-27HP230V1 Qty: 1
18k BTU MrCool Olympus Ductless Wall Mounted Air Handler 18k BTU MrCool Olympus Ductless Wall Mounted Air Handler Item: HA11051 Model: O-MULTI18HP-WMAH-230 Qty: 2
MrCool

Contractors

Up to 30% Off - Call for Info

Call 270-575-9595 Now

What's Included

What customers are saying...

 

Overview

Technology has come a long way when it comes to home comfort systems, and the 23 SEER MRCOOL ductless heat pump system is a prime example! Heat pump technology allows the use of refrigerant flow and electricity to provide you with heat, instead of using gas or propane, making it a fantastic option if these gases are not available in your area and your climate demands both heating and cooling.

Heat pump technology utilizes a reversing valve that switches refrigerant flow from your condenser to your wall mounted unit. Ultimately, this turns your condensing unit into a cooling coil and your wall mounted unit into a heater. Be careful in climates that have extremely cold climates as ductless heat pump units do have their limitations. Most heat pump units see there limits when atmospheric temperatures fall below -20 degrees Celsius ( -4 degrees F Fahrenheit ).

Ductless heat pump units also give you the advantage of installing the wall mounted units exactly where you want them. If you currently have a space that’s always warm in the summer and always cold in the winter, this might be an excellent option for you. Another benefit is when your replacing baseboard heaters. Baseboard heaters don't allow for any air filtration as there is no fan associated with them. Adding a wall mounted unit, that has an included filter, allows you to remove dust and allergens from the air, giving you cleaner and a higher quality of air distribution. Baseboard convection heaters also don’t give you the benefit of circulating the warm air with the power of a fan. So if you’re looking to hit every corner of your room, take a look at this Olympus package brought to you by MRCOOL.

Just because you live in a large space doesn't mean you can't use a MRCOOL Olympus Ductless Heat Pump Split System to get the comfort, efficiency, and savings you want. This 36k system gives you dual wall-mounted air handlers with 18k heating and cooling power each. Energy-saving features include Sleep Mode and Louver Position Memory. Each air handler leads back to the MRCOOL MULTI3-27HP230V1 condenser with 36k BTU of power, and a host of energy efficient features that include ozone-safe R-410A refrigerant. Variable-speed technology helps this system operate at 23 SEER.

Warranty Terms

For a full description of all warranties applicable to this product as well as individual manufacturer requirements, please review the manufacturer's consumer brochure and/or product warranty documents.  Online warranty registration must be completed within 60 days of installation.  Due to state laws, online registration is not required in California or Quebec. Call for warranty availability on scratch & dent and surplus items.

For additional warranty information, click here.

Specifications

Model MULTI3-27HP230V1,O-MULTI18HP-WMAH-230,O-MULTI18HP-WMAH-230
UPC 856536005848
AHRI Number 8977708
Bundle Avg Coverage Area 1,000 - 1,200 Sq Ft
Bundle Cooling Capacity 2 Ton
Bundle Cooling Efficiency 19 SEER and Above
EER 12.5
Heat Pump Efficiency (HSPF) 10.3
Series Olympus
Zones 2
Region Compatibility Nationwide
Popular Applications Apartment, Duplex, Hotel Room, Office, Single Family Home
California Residents see Prop 65 WARNING

MULTI3-27HP230V1 Specifications:

Model MULTI3-27HP230V1
UPC 856536005848
Avg Coverage Area 1,000 - 1,200 Sq Ft
Compressor Inverter
Cooling Capacity 2 Ton
Electrical Phase 1-Phase
Heat Pump Efficiency (HSPF) 10.3
Line Set Connection Type Flared
Liquid Line Size 1/4 inch
Max Overcurrent Protection 35 amps
Primary Heating Capacity 25,001 - 30,000 BTU
Product Height (in) 32
Product Length (in) 16
Product Width (in) 37
Cooling Efficiency 19 SEER and Above
Series Olympus
System Application Type Ductless Split Systems
Voltage 240
Warranty 5 Year Parts, 7 Year Compressor
Weight (lbs) 150.0000
Region Compatibility Nationwide

O-MULTI18HP-WMAH-230 Specifications:

Model O-MULTI18HP-WMAH-230
UPC 856536005817
Air Flow Direction Horizontal
Configuration Wall Mounted
Blower Motor Variable Speed
Cooling Capacity 1.5 Ton
Electrical Phase 1-Phase
Heat Strip Compatibility NA
Line Set Connection Type Flared
Liquid Line Size 1/4 inch
Max Overcurrent Protection 25 amps
Product Height (in) 12
Product Length (in) 9
Product Width (in) 39
Series Olympus
Suction Line Size 1/2 inch
System Application Type Ductless Split Systems
Voltage 240
Warranty 5 Year Parts
Weight (lbs) 27.0000

Reviews

Q & A

Do you have questions about this product?

Sort by ASC
Can the two air handlers be mounted in one large room to cover 1,800 sqft without interfering with each other?
Does this system come with the r-410 charges lines?