27k BTU 25 SEER2 MrCool Olympus In-Duct Heat Pump Split System - 2 Zone - 9k + 18k - R454B
MRCOOL

Accessories
Description / Documents
It doesn’t matter if you’re adding climate control to a couple rooms with unique considerations your central system can’t accommodate, or if you’re providing HVAC equipment to a structure that is currently lacking temperature regulation, zoned systems are a game changer. With a 27k BTU 25 SEER2 MrCool Olympus In-Duct Heat Pump Split System - 2 Zone - 9k + 18k - R454B, you can ensure comfort in any season. Backed by ETL listing, as well as Energy Star and AHRI certifications, the MrCool Olympus Heat Pump validates every efficiency, performance, and safety claim by passing intensive evaluations from independent agencies. Guarantee the temperatures you want all year long with a 27k BTU MrCool Split System.
Packed with powerful features, the condenser in the 27k BTU 25 SEER2 MrCool Olympus In-Duct Heat Pump Split System - 2 Zone - 9k + 18k - R454B can support the unique needs of your space with ease. Inverter technology gives the MrCool Condenser the capacity to shrink the distance the temperature is allowed to fluctuate from your given set-point, optimizing both efficiency and comfort. The use of R454B refrigerant ensures eco-friendly operation, sporting zero ozone depletion potential and a decreased global warming potential compared to older refrigerants. For a solution that can fight off triple-digit heat and below freezing temperatures, the MrCool Olympus Split System is the tool for the task.
Providing the airflow you need without taking up wall space, the two ceiling recessed air handlers in the 27k BTU 25 SEER2 MrCool Olympus In-Duct Heat Pump Split System - 2 Zone - 9k + 18k - R454B are a great option for residential and light commercial applications. Thanks to their flush installation, the 9k and 18k BTU MrCool Ceiling Recessed Air Handlers are ideal for spaces where aesthetic is a priority. Between the handheld remote and wall-mounted wired controller, you’ll have all the tools you need to ensure the MrCool Olympus Split System gives you the year-round comfort you deserve.
Between the performance you want and the peace of mind that comes from a warranty that includes 7-year coverage on the compressor, 5-year coverage on the parts, and the option to extend compressor coverage to a limited lifetime with enrollment in the MrCool Care Program, it’s easy to see the benefits. Bring home a 27k BTU 2 Zone MrCool Olympus In-Duct Heat Pump Split System with one 9k BTU and one 18k BTU Ceiling Recessed Air Handler equipped with R454B refrigerant today and ensure the exact indoor temperatures you want in every season.
From the Manufacturer
Customer Reviews / Q&A
Specifications
System Overview
| Model | M227HP23RD02C |
|---|---|
| AHRI Number | 217291695 |
| Bundle Avg Coverage Area | 1,000 - 1,200 Sq Ft |
| Bundle Cooling Capacity | 2 Ton |
| Bundle Cooling Efficiency (SEER2) | 25 |
| Heat Pump Efficiency (HSPF2) | 9.5 |
| Series | Olympus |
| Region Compatibility | Nationwide |
MULTI4-27HP230C-O Specifications:
| Model | MULTI4-27HP230C-O |
|---|---|
| UPC | 840255587792 |
| AHRI Number | 217291696 |
| Product Height (in) | 31.9 |
| Avg Coverage Area | 1,000 - 1,200 Sq Ft |
| Product Length (in) | 16.1 |
| Compressor | Inverter |
| Product Width (in) | 37.2 |
| Cooling Capacity | 2 Ton |
| Electrical Phase | 1-Phase |
| Heat Pump Efficiency (HSPF2) | 9.5 |
| Line Set Connection Type | Flared |
| Liquid Line Size | 1/4 inch |
| Max Overcurrent Protection | 25 amps |
| Weight (lbs) | 138.900000 |
| Primary Heating Capacity | 25,001 - 30,000 BTU |
| Refrigerant | R-454b |
| Cooling Efficiency (SEER2) | 21 |
| Series | Olympus ES |
| System Application Type | Ductless Split Systems |
| Voltage | 240 |
| Warranty | Lifetime, 5 Year Parts, 7 Year Compressor |
| Region Compatibility | Nationwide |
DUCT-09HP-230B-O Specifications:
| Model | DUCT-09HP-230B-O |
|---|---|
| UPC | 840255587662 |
| Product Height (in) | 7.9 |
| Configuration | Ceiling Mounted |
| Product Length (in) | 19.9 |
| Air Flow Direction | Horizontal |
| Product Width (in) | 27.6 |
| Blower Motor | Variable Speed |
| Cooling Capacity | Less than 1 Ton |
| Electrical Phase | 1-Phase |
| Line Set Connection Type | Flared |
| Liquid Line Size | 1/4 inch |
| Max Overcurrent Protection | 15 amps |
| Weight (lbs) | 39.500000 |
| Refrigerant | R-454b |
| Series | Olympus ES |
| Suction Line Size | 3/8 inch |
| System Application Type | Ductless Split Systems |
| Voltage | 240 |
| Warranty | Lifetime, 5 Year Parts |
DUCT-18HP-230B-O Specifications:
| Model | DUCT-18HP-230B-O |
|---|---|
| UPC | 840255587686 |
| Product Height (in) | 8.3 |
| Configuration | Ceiling Mounted |
| Product Length (in) | 26.5 |
| Air Flow Direction | Horizontal |
| Product Width (in) | 34.7 |
| Blower Motor | Variable Speed |
| Cooling Capacity | 1.5 Ton |
| Electrical Phase | 1-Phase |
| Line Set Connection Type | Flared |
| Liquid Line Size | 1/4 inch |
| Max Overcurrent Protection | 15 amps |
| Weight (lbs) | 54.500000 |
| Refrigerant | R-454b |
| Series | Olympus ES |
| Suction Line Size | 1/2 inch |
| System Application Type | Ductless Split Systems |
| Voltage | 240 |
| Warranty | Lifetime, 5 Year Parts |