18k BTU 22.5 SEER MrCool Olympus Ductless Heat Pump Split System - 2 Zone Concealed Duct - 9k+9k

Item: HA11724
Models: MULTI2-18HP230V1, DUCT-09HP-230
Condition: New

18k BTU 22.5 SEER MrCool Olympus Ductless Heat Pump Split System - 2 Zone Concealed Duct - 9k+9k Zoom

Photo Gallery

Related Videos

Can you be comfortable in two places at once? Absolutely, with this 18k BTU, 22.5 SEER MRCOOL Olympus Ductless Heat Pump Split System. The MULTI2-18HP230V1 condenser includes advanced Inverter variable-speed compressor technology and self-diagnostic Leak Detect technology. Inside, two 9k Recessed Duct air handlers treat you to perfect comfort with features like Auto Swing and Louver Position Memory. Two remotes are included. This system features a 7 year comprssor warranty and 5 year parts warranty.

Availability: In stock

As low as: $2,907.00

Price as configured: $2,907.00

Ingram Financing
 
18k BTU MrCool Olympus Ductless Heat Pump Condenser - 2 Zone 18k BTU MrCool Olympus Ductless Heat Pump Condenser - 2 Zone Item: HA11045 Model: MULTI2-18HP230V1 Qty: 1

* Required Fields

Ships Within 1-2 Business Days

Up To $500 Cash Back

Get everything right and save time

Contact an expert now.

Call: 1-270-575-9595

or click here to chat

This Bundle Includes

18k BTU MrCool Olympus Ductless Heat Pump Condenser - 2 Zone 18k BTU MrCool Olympus Ductless Heat Pump Condenser - 2 Zone Item: HA11045 Model: MULTI2-18HP230V1 Qty: 1
9k BTU MrCool Olympus Ceiling Recessed Air Handler 9k BTU MrCool Olympus Ceiling Recessed Air Handler Item: HA11056 Model: DUCT-09HP-230 Qty: 2

Overview

Need a ductless home comfort solution but can't stand the site of wall mounted unit? MRCOOL has a fantastic solution that keeps the units hidden without sacrificing functionality. The two zone ductless heat pump concealed duct units by MRCOOL are installed in ceiling spaces behind drywall, making them virtually undetectable. These unit have been made for various types of applications and can be used in hotel rooms or offices, but, most importantly, in your home. Installing a concealed duct mini split system is rewarding as you won't have any of the components disrupting your home decor. These units are just one example of the many different products that MrCool carries. No matter what the application is, the MRCOOL Olympus series has a ductless home comfort solution that will fit in with any project.

Like many other MRCOOL products, many of your installation components are supplied in this package. Included is the insulated lineset, that has been made specifically for this system. Having an insulated lineset is important when it comes to air conditioning units, as water condenses on cold surfaces during humid conditions. Without insulation, water would condense on the lineset and create a pool of water that can damage your home or building envelope. Also included are two wired controllers, one for each unit, that can be mounted on a wall in proximity to the concealed duct unit. Make sure you install the controller in a location where it's not directly in sunlight, as it can simulate warmer conditions than are actually in your comfort zone.

Can you be comfortable in two places at once? Absolutely, with this 18k BTU, 22.5 SEER MRCOOL Olympus Ductless Heat Pump Split System. The MULTI2-18HP230V1 condenser includes advanced Inverter variable-speed compressor technology and self-diagnostic Leak Detect technology. Inside, two 9k Recessed Duct air handlers treat you to perfect comfort with features like Auto Swing and Louver Position Memory. Two remotes are included. This system features a 7 year comprssor warranty and 5 year parts warranty.

Warranty Terms

For a full description of all warranties applicable to this product as well as individual manufacturer requirements, please review the manufacturer's consumer brochure and/or product warranty documents.  Online warranty registration must be completed within 60 days of installation.  Due to state laws, online registration is not required in California or Quebec. Call for warranty availability on scratch & dent and surplus items.

For additional warranty information, click here.

Specifications

Model MULTI218HP230RD00
UPC 856536005831
AHRI Number 8977707
Bundle Avg Coverage Area 750 - 900 Sq Ft
Bundle Cooling Capacity 1.5 Ton
Bundle Cooling Efficiency 19 SEER and Above
EER 12.5
Heat Pump Efficiency (HSPF) 10.3
Series Olympus
Zones 2
Region Compatibility Nationwide
Popular Applications Apartment, Duplex, Hotel Room, Office, Single Family Home
California Residents see Prop 65 WARNING

MULTI2-18HP230V1 Specifications:

Model MULTI2-18HP230V1
UPC 856536005831
Avg Coverage Area 750 - 900 Sq Ft
Compressor Inverter
Cooling Capacity 1.5 Ton
Electrical Phase 1-Phase
Heat Pump Efficiency (HSPF) 10.3
Line Set Connection Type Flared
Liquid Line Size 1/4 inch
Max Overcurrent Protection 25 amps
Primary Heating Capacity 15,001 - 20,000 BTU
Product Height (in) 28
Product Length (in) 14
Product Width (in) 33
Cooling Efficiency 19 SEER and Above
Series Olympus
System Application Type Ductless Split Systems
Voltage 240
Warranty 5 Year Parts, 7 Year Compressor
Weight (lbs) 106.0000
Region Compatibility Nationwide

DUCT-09HP-230 Specifications:

Model DUCT-09HP-230
UPC 853962006517
Air Flow Direction Horizontal
Configuration Ceiling Mounted
Blower Motor Variable Speed
Cooling Capacity Less than 1 Ton
Electrical Phase 1-Phase
Heat Strip Compatibility NA
Line Set Connection Type Flared
Liquid Line Size 1/4 inch
Max Overcurrent Protection 15 amps
Product Height (in) 8
Product Length (in) 25
Product Width (in) 28
Series Olympus
Suction Line Size 3/8 inch
System Application Type Ductless Split Systems
Voltage 240
Warranty 5 Year Parts
Weight (lbs) 40.0000

Reviews

Q & A

Do you have questions about this product?

Sort by ASC
Does the concealed duct units have a built in condensation pump?
does air handlers have pumps to vacate condensation or is it done by gravity only
Are plenum kits available for the 9k BTU ceiling recessed air handler? My install requires short runs of duct to some small rooms.
Does this unit only work with the factory supplied thermostat or could one use a different (nest) thermostat?