48k BTU 22.4 SEER MrCool Olympus Ductless Heat Pump Split System - 2 Zone Concealed Duct - 18k+24k

Item: HA11830
Models: MULTI5-48HP230V1, DUCT-18HP-230, DUCT-24HP-230
Condition: New

48k BTU 22.4 SEER MrCool Olympus Ductless Heat Pump Split System - 2 Zone Concealed Duct - 18k+24k Zoom

Photo Gallery

Related Videos

The MRCOOL Olympus Ductless Heat Pump series is all about flexibility (and awesomeness). Although this package is configured for two zones, the condenser that powers it can accommodate up to a total of five zones. This system includes two concealed duct air handlers. A 24k unit is suitable to cover about 1000 square feet, and an 18k unit is calibrated for around 750 square feet.

Availability: Out of stock

As low as: $5,612.00

Price as configured: $5,612.00

Call for availability

Up To $500 Cash Back

Get everything right and save time

Contact an expert now.

Call: 1-270-575-9595

or click here to chat

This Bundle Includes

18k BTU MrCool Olympus Ceiling Recessed Air Handler 18k BTU MrCool Olympus Ceiling Recessed Air Handler Item: HA11058 Model: DUCT-18HP-230 Qty: 1
24k BTU MrCool Olympus Ceiling Recessed Air Handler 24k BTU MrCool Olympus Ceiling Recessed Air Handler Item: HA11059 Model: DUCT-24HP-230 Qty: 1

Overview

Avoid all of the costs associated with craning, ductwork, roof curbs and starting up your equipment with the purchase of this Olympus HVAC system for your business. Rooftops are typically used to save space and introduce fresh air, as it's typically a requirement for commercial applications. But did you know this system can be installed in your ceiling space? With features like that, you will save money from your installation, purchase, and maintenance! Gone are the days of trundling around outside in the chilly winter weather to replace filters. With this system, you can easily replace or clean the filters yourself from inside your building. With a great compressor and parts warranty, you can sleep easy when you install a MRCOOL ductless product.

This 48,000 BTU MRCOOL Olympus ductless heat pump system comes with 2 zone concealed air handlers that can be installed behind drywall as the name implies. The 12,000 BTU air handler is ideal for spaces that are between 450 to 550 square feet and the 18,000 BTU air handler can serve a space between 700 to 1000 square feet. If you would like to install both air handlers in one space, they can be combined to serve 1150 to 1550 square feet. MRCOOL packages also provide you with nearly everything you need to get the job completed. Included with the unit is a factory-charged heat pump condenser, 2 air handling units, and 2 wired controllers.

The MRCOOL Olympus Ductless Heat Pump series is all about flexibility (and awesomeness). Although this package is configured for two zones, the condenser that powers it can accommodate up to a total of five zones. This system includes two concealed duct air handlers. A 24k unit is suitable to cover about 1000 square feet, and an 18k unit is calibrated for around 750 square feet.

Warranty Terms

For a full description of all warranties applicable to this product as well as individual manufacturer requirements, please review the manufacturer's consumer brochure and/or product warranty documents.  Online warranty registration must be completed within 60 days of installation.  Due to state laws, online registration is not required in California or Quebec. Call for warranty availability on scratch & dent and surplus items.

For additional warranty information, click here.

Specifications

Model MULTI248HP230RD08
UPC 856536005862
AHRI Number 8977710
Bundle Avg Coverage Area 2,000 - 2,400 Sq Ft
Bundle Cooling Capacity 4 Ton
Bundle Cooling Efficiency 19 SEER and Above
EER 12.5
Heat Pump Efficiency (HSPF) 10.2
Series Olympus
Zones 2
Region Compatibility Nationwide
Popular Applications Apartment, Duplex, Hotel Room, Office, Single Family Home
California Residents see Prop 65 WARNING

MULTI5-48HP230V1 Specifications:

Model MULTI5-48HP230V1
UPC 856536005862
Avg Coverage Area 2,000 - 2,400 Sq Ft
Compressor Inverter
Cooling Capacity 4 Ton
Electrical Phase 1-Phase
Heat Pump Efficiency (HSPF) 10.2
Line Set Connection Type Flared
Liquid Line Size 1/4 inch
Max Overcurrent Protection 50 amps
Primary Heating Capacity 45,001 - 50,000 BTU
Product Height (in) 52
Product Length (in) 16
Product Width (in) 37
Cooling Efficiency 19 SEER and Above
Series Olympus
System Application Type Ductless Split Systems
Voltage 240
Warranty 5 Year Parts, 7 Year Compressor
Weight (lbs) 224.0000
Region Compatibility Nationwide

DUCT-18HP-230 Specifications:

Model DUCT-18HP-230
UPC 853962006531
Air Flow Direction Horizontal
Configuration Ceiling Mounted
Blower Motor Variable Speed
Cooling Capacity 1.5 Ton
Electrical Phase 1-Phase
Heat Strip Compatibility NA
Line Set Connection Type Flared
Liquid Line Size 1/4 inch
Max Overcurrent Protection 15 amps
Product Height (in) 8
Product Length (in) 25
Product Width (in) 36
Series Olympus
Suction Line Size 1/2 inch
System Application Type Ductless Split Systems
Voltage 240
Warranty 5 Year Parts
Weight (lbs) 51.0000

DUCT-24HP-230 Specifications:

Model DUCT-24HP-230
UPC 853962006548
Air Flow Direction Horizontal
Configuration Ceiling Mounted
Blower Motor Variable Speed
Cooling Capacity 2 Ton
Electrical Phase 1-Phase
Heat Strip Compatibility NA
Line Set Connection Type Flared
Liquid Line Size 3/8 inch
Max Overcurrent Protection 15 amps
Product Height (in) 11
Product Length (in) 25
Product Width (in) 36
Series Olympus
Suction Line Size 5/8 inch
System Application Type Ductless Split Systems
Voltage 240
Warranty 5 Year Parts
Weight (lbs) 57.0000

Reviews

Q & A

Do you have questions about this product?

Sort by ASC
I have a 1600 sq ft building divided into 1300 sq ft garage area with 14 ft ceiling and 300 sq ft with 12 ft ceiling. Located in N Georgia. Walls and ceiling are insulated to 20 R. Is it possible to split a 48k unit into a 12 and 36 k split that would handle these spaces.
Can multiple Air Handlers be connected to one condenser outlet port - using a Y in the line set? What is the maximum BTU output for a condenser outlet port or will each port support the full 48k BTU?. My 2 Air Handlers are in the attic... I would like to use the existing linset in the wall and Y off to the air handlers. I see a Line set size requirement in the Air Handler spec, but it doesn't give Condenser port Max BTU details.