Overview
If you are finding that your garage is too cold to work in during the winter and too hot to work in during the summer, this system is a great option for you! Heat pump technology offers you heating and cooling capabilities with only the use of refrigerant flow, so you no longer need gas or propane for your HVAC system. You will also be glad to hear that this system comes fully equipped with efficient components and is rated at 22.4 SEERS. This system was designed to withstand the test of time for years, and with a compressor and parts warranty, you will have peace of mind if a problem were to ever arise.
The 48,000 BTU MRCOOL Olympus ductless heat pump system comes equipped with 4 zone concealed duct air handlers. Each of the two 9000 BTU air handlers are great for spaces 350 to 400 square feet each. The 12,000 BTU unit can serve a space 450 to 550 square feet and the 24,000 BTU air handler can serve spaces up to 1500 square feet. If you decide to combine all four units in one space, the condenser can give you a total square footage of 2000 to 4000 square feet. If this system is too large or too small, visit our similar systems offers by MRCOOL to find the ideal system for your home.
For houses that weren't built with central heating and air conditioning, the old school route to comfort meant constant waste---of money, energy, and environment. MRCOOL cuts the waste and brings the rewards with Olympus Ductless Heat Pump Split Systems. This powerful version is built on a MULTI5-48HP230V1 condenser, packing 54k BTU capacity and rated 22.4 SEER. Four inside zones are covered by size-selected concealed duct air handlers, ranging from a 24k unit to two 9k units.
Warranty Terms
For a full description of all warranties applicable to this product as well as individual manufacturer requirements, please review the manufacturer's consumer brochure and/or product warranty documents. Online warranty registration must be completed within 60 days of installation. Due to state laws, online registration is not required in California or Quebec. Call for warranty availability on scratch & dent and surplus items.
Installation of any product must comply with all applicable codes and regulations. The service of a certified and trained electrical technician may be required for the installation process.
Specifications
Model | MULTI5-48HP230V1,DUCT-09HP-230,DUCT-09HP-230,DUCT-12HP-230,DUCT-24HP-230 |
---|---|
UPC | 856536005862 |
AHRI Number | 8977710 |
Bundle Avg Coverage Area | 2,000 - 2,400 Sq Ft |
Bundle Cooling Capacity | 4 Ton |
Bundle Cooling Efficiency | 19 SEER and Above |
EER | 12.5 |
Heat Pump Efficiency (HSPF) | 10.2 |
Series | Olympus |
Zones | 4 |
Region Compatibility | Nationwide |
Popular Applications | Apartment, Duplex, Hotel Room, Office, Single Family Home |
California Residents | see Prop 65 WARNING |
MULTI5-48HP230V1 Specifications:
Model | MULTI5-48HP230V1 |
---|---|
UPC | 856536005862 |
Avg Coverage Area | 2,000 - 2,400 Sq Ft |
Compressor | Inverter |
Cooling Capacity | 4 Ton |
Electrical Phase | 1-Phase |
Heat Pump Efficiency (HSPF) | 10.2 |
Line Set Connection Type | Flared |
Liquid Line Size | 1/4 inch |
Max Overcurrent Protection | 50 amps |
Primary Heating Capacity | 45,001 - 50,000 BTU |
Product Height (in) | 52 |
Product Length (in) | 16 |
Product Width (in) | 37 |
Cooling Efficiency | 19 SEER and Above |
Series | Olympus |
System Application Type | Ductless Split Systems |
Voltage | 240 |
Warranty | 5 Year Parts, 7 Year Compressor |
Weight (lbs) | 224.0000 |
Region Compatibility | Nationwide |
DUCT-09HP-230 Specifications:
Model | DUCT-09HP-230 |
---|---|
UPC | 853962006517 |
Air Flow Direction | Horizontal |
Configuration | Ceiling Mounted |
Blower Motor | Variable Speed |
Cooling Capacity | Less than 1 Ton |
Electrical Phase | 1-Phase |
Heat Strip Compatibility | NA |
Line Set Connection Type | Flared |
Liquid Line Size | 1/4 inch |
Max Overcurrent Protection | 15 amps |
Product Height (in) | 8 |
Product Length (in) | 25 |
Product Width (in) | 28 |
Series | Olympus |
Suction Line Size | 3/8 inch |
System Application Type | Ductless Split Systems |
Voltage | 240 |
Warranty | 5 Year Parts |
Weight (lbs) | 40.0000 |
DUCT-12HP-230 Specifications:
Model | DUCT-12HP-230 |
---|---|
UPC | 853962006524 |
Air Flow Direction | Horizontal |
Configuration | Ceiling Mounted |
Blower Motor | Variable Speed |
Cooling Capacity | 1 Ton |
Electrical Phase | 1-Phase |
Heat Strip Compatibility | NA |
Line Set Connection Type | Flared |
Liquid Line Size | 1/4 inch |
Max Overcurrent Protection | 15 amps |
Product Height (in) | 8 |
Product Length (in) | 25 |
Product Width (in) | 28 |
Series | Olympus |
Suction Line Size | 1/2 inch |
System Application Type | Ductless Split Systems |
Voltage | 240 |
Warranty | 5 Year Parts |
Weight (lbs) | 40.0000 |
DUCT-24HP-230 Specifications:
Model | DUCT-24HP-230 |
---|---|
UPC | 853962006548 |
Air Flow Direction | Horizontal |
Configuration | Ceiling Mounted |
Blower Motor | Variable Speed |
Cooling Capacity | 2 Ton |
Electrical Phase | 1-Phase |
Heat Strip Compatibility | NA |
Line Set Connection Type | Flared |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 15 amps |
Product Height (in) | 11 |
Product Length (in) | 25 |
Product Width (in) | 36 |
Series | Olympus |
Suction Line Size | 5/8 inch |
System Application Type | Ductless Split Systems |
Voltage | 240 |
Warranty | 5 Year Parts |
Weight (lbs) | 57.0000 |